💡TDS7104 Oscilloscope: 1 GHz Bandwidth, 10Gs/s Sample Rate
This 1 GHz oscilloscope packs 10Gs/s sample rate
TL;DR
The TDS7104 oscilloscope boasts 1 GHz bandwidth and 10Gs/s sample rate, but sample rates drop with channel usage. It runs VxWorks on a PowerPC board and has a 6 GB hard drive. Common issues include dead batteries and leaking capacitors.
The TDS7104 oscilloscope is a beast with 1 GHz bandwidth and a max sample rate of 10Gs/s. However, using multiple channels reduces the sample rate to 5 Gs/s for 2 channels and 2.5 Gs/s for 1 or 2 channels. This oscilloscope runs VxWorks on a PowerPC-based controller board and has a 6 GB hard drive. Common issues include dead CMOS and PowerPC backup batteries, dead hard drives, and leaking power supply capacitors. If you're dealing with high-speed signals, this oscilloscope can be a game changer, but be prepared for maintenance issues.
Key Points
TDS7104 oscilloscope has 1 GHz bandwidth and 10Gs/s sample rate.
Sample rates drop to 5 Gs/s for 2 channels and 2.5 Gs/s for 1 or 2 channels.
Runs VxWorks on a PowerPC-based controller board with 6 GB hard drive.
Common failures include dead CMOS and PowerPC backup batteries, dead hard drives.
Leaking power supply capacitors are another frequent issue.
Why It Matters
If you're working with high-speed signals and need precise measurements, the TDS7104's 1 GHz bandwidth and 10Gs/s sample rate make it a powerful tool. However, maintenance is crucial due to common failures like dead batteries and leaking capacitors. Teams using this oscilloscope should plan for regular maintenance to avoid downtime.
Frequently Asked Questions
Why does this matter?
If you're working with high-speed signals and need precise measurements, the TDS7104's 1 GHz bandwidth and 10Gs/s sample rate make it a powerful tool. However, maintenance is crucial due to common failures like dead batteries and leaking capacitors. Teams using this oscilloscope should plan for regular maintenance to avoid downtime.
What happened?
The TDS7104 oscilloscope boasts 1 GHz bandwidth and 10Gs/s sample rate, but sample rates drop with channel usage. It runs VxWorks on a PowerPC board and has a 6 GB hard drive. Common issues include dead batteries and leaking capacitors.
Comments
Be the first to comment
Enjoyed this article?
Get it daily. 7am. Free. Reads in 5 minutes.
Join 3,436 builders reading daily.